Freight Carrier · Kermit, TX
BUCKO ENERGY SERVICES LLC
416 N AVENUE C · Kermit, TX 79745-3416
AUTHORIZED FOR:
(432) 208-3990
Tap to call
- MC #1299404
- USDOT #3664872 USDOT Active
- 6Power Units
- 6Drivers
- CarrierEntity Type
About this carrier
BUCKO ENERGY SERVICES LLC is a Kermit, TX freight carrier that is authorized for: in the state of Texas. This company has 6 truck(s) in their fleet and 6 truck drivers. Their motor carrier number is MC-1299404 and their USDOT number is 3664872.
Sourced from FMCSA SAFER · last filed 01/08/2026 · last updated Jun 15, 2026.Carrier Details
- Operating Status AUTHORIZED FOR:
- MCS-150 Filed 01/08/2026
- MCS-150 Mileage 256,000 (2025)
Authority & Operations
Operation Classification
- Authorized for Hire
- Private (Property)
Carrier Operation
- Interstate
Operating Territory
Inspection activity Inspected in 1 state over the past 24 months: TX (6). Home base: Kermit, Texas.
Safety Record
Crashes (24 mo)
-
0Fatal
- 0Injury
- 0Tow
- 0Total
Behavior Categories (BASICs)
CategoryMeasureViolations
Unsafe Driving
0
0
Crash Indicator
Not Public
—
Hours of Service
0
0
Vehicle Maintenance
19.15
5
Drugs / Alcohol
0
0
Hazmat
Not Public
—
Driver Fitness
0
0
Inspection Summary
- 6Total
- 1Clean
- 5With violations
24-month window ending May 15, 2026
Violations Cited 17 unique codes
Critical 3
- 393.75(a)(3)Tire-flat and/or audible air leak
- 393.75(c)Tire-other tread depth less than 2/32 of inch measured in a major tread groove
- 393.207(c)Leaf spring assembly defective/missing
Vehicle Maintenance 14
- 393.9HInoperable head lamps
- 393.55(e)No or Defective ABS Malfunction Indicator Lamp for trailer manufactured after 03/01/1998
- 393.45DLPCBrake Connections with Leaks - Connection to Power Unit
- 393.47(d)All Brakes - Insufficient brake lining thickness
- 393.48(a)Inoperative/defective brakes
- 393.55(d)(3)No or Defective ABS Malfunction Indicator for towed vehicles on vehicles manufactured after February 2001
- 393.11TLTruck-Tractor lower rear mud flaps retroreflective sheeting / reflex reflective material requirements for vehicles manufactured after July 1997
- 396.5(b)Oil and/or grease leak
- 393.11No or defective lighting devices or reflective material as required
- 393.9Inoperable Required Lamp
- 393.95(a)No/discharged/unsecured fire extinguisher
- 393.95(b)Emergency Equipment - A power unit requiring fuses - missing a spare fuse for a required part or accessory (e.g., lamps required by 393.11, ABS lights or low air warning light).
- 393.95(f)Emergency Equipment - Stopped vehicle warning devices missing or improper
- 393.60(c)Windshield - Damaged or Discolored
Locations
Physical Address
BUCKO ENERGY SERVICES LLC416 N AVENUE C
KERMIT, TX 79745-3416
Mailing Address
Same as physical.